Product
Description
The NSG 4070 is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to IEC / EN 61000-4-6, Namur and several automotive BCI standards.
6 dB - 50 Ω attenuators, particularly for minimising reflection losses in tests per IEC/EN 61000-4-6 also useful for general purposes.
1 MHz to 1 GHz 30 Watt Broadband Power Amplifier
10 kHz TO 100 MHz 110 Watt Class A Broadband Amplifier
10 kHz to 100 MHz 400 Watt Class A Broadband Amplifier
150 kHz to 230 MHz 35 Watt Class A Broadband Amplifier
150 kHz to 230 MHz 80 Watt Class A Broadband Amplifier
10 kHz to 250 MHz 2500 Watt Class A Broadband Amplifier
10 KHz to 400 MHz 100 Watt Class A Broadband Amplifier
10 kHz to 400 MHz 260 Watt Class A Broadband Amplifier
CDN AF Series
CDN CAN Series
CDN M Series
CDN S Series
CDN T Series
The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ.
Compliance 5 is sophisticated EMC laboratory control software designed to make RF Susceptibility/Immunity testing fast, efficient, compliant, accurate and simple.
This high power dual directional coupler has been specifically designed for EMC immunity applications.
Ferrite tube for immunity test according to IEC / EN 61000-4-6, large diameter of 35 mm
The Input/Output Box, in short IOB 4000, is an ideal addition for electromagnetic immunity test systems.
ISN S series is designed for measurements on coaxial telecommunication lines.
The ISN T2 is designed for measurements on one unscreened balanced pair for cable cat. 3 and cat. 5.
The ISN T4 is designed for measurements on one or two unscreened balanced pairs for cable cat. 3 and cat. 5.
The ISN T8-Cat6 is designed for measurements on up to four unscreened single balanced pairs with cable category cat. 6.
The KEMA 801B is recommended as an additional decoupling network (ferrite tube clamp) for immunity test according to IEC/EN 61000-4-6 when using the clamp injection method.
The normative Annex A of IEC/EN 61000-4-6 gives additional information regarding the clamp injection. The KEMZ 801 is similar to the described EM clamp in the standard and injects the disturbance signal through a combination of inductive and capacitive coupling.
The monitoring device MD 4070 can be used as an active or passive current sensor probe to measure the current in a conductor without connecting it directly.
The PMU 6003 is designed for connection to the USB interface. It includes software that allows multiple power meter readouts at the same time.
The PCJ 9201 meets all the requirements and provides additionally a save way for measuring the insertion loss of current sensing probes and monitoring probes.
RF Switch Network
Teseq provides with the WIN 6000 a device control software with NSG 4070 and ITS 6006 for performing conducted and radiated susceptibility tests as defined by international standards.
AMETEK CTS GmbH
Sternenhofstr. 15
4153 Reinach, Switzerland
Tel.+ 41 61 204 41 00
marketing.cts@ametek.com
Managing Directors:
Brian Huntsman
Astrid Wälchli Schreiber
VAT-ID: CHE-179.452.414
Register of companies: CH-280.4.015.069-3