Back to home
Ametek
 

MFO 6502

Automatic Power Line Frequency Magnetic Field

MFO 6502zoom
  • Complies with IEC/EN 61000-4-8
  • Integrated function unit to NSG 3000 series generators
  • Magnetic field test with up to 40 A/m
  • 50/60 Hz frequency selection
 

Electronic devices containing components sensitive to magnetic fields need to be tested for immunity to electromagnetic fields. Product standards define the applicability of such tests and specify the field strength. The basic standard IEC/EN 61000-4-8 describes the test methods for magnetic fields with powerline frequencies.

The MFO 6502 is an auxiliary device for the NSG 3000 series generators and enables fully automatic power line magnetic field testing. It is connected via the system cable to the NSG 3000 generator and is embedded in the configuration management, the software control and the automatic report mechanism.

 
Parameter Value
With magnetic antenna loop INA 701

Field strength, low range: 0.08 to 0.4 A/m (80 to 400 mA drive current)
High range: 0.2 to 3.6 A/m (200 mA to 4.1 A drive current)

With magnetic antenna loop INA 702

Field strength, low range: 0.8 to 4 A/m (80 to 400 mA drive current)
High range: 2 to 40 A/m (200 mA to 4.1 A drive current)

With magnetic antenna loop INA 703

Field strength, low range: 2.7 to 13.6 A/m (80 to 400 mA drive current)
High range: 6.8 to 130 A/m (200 mA to 4.1 A drive current)

Total harmonic distortion (THD)

<8% for levels 1 to 4, <3.5% at max. output

Test frequency

Selectable 50 and 60 Hz ±3%

Magnetic field adjustment

Software driven

 

Datasheet

User manual

Gallery

 
 
 
 

Imprint

AMETEK CTS GmbH
Sternenhofstr. 15
4153 Reinach, Switzerland
Tel.+ 41 61 204 41 00
marketing.cts@ametek.com

Managing Directors:
Brian Huntsman
Astrid Wälchli Schreiber
VAT-ID: CHE-179.452.414
Register of companies: CH-280.4.015.069-3


 
 
By continuing to use the site, you agree to our Privacy and Cookie Policy.