Probably the largest EMC challenge in recent years, the addition of green mobility adds a whole new range of complicated DUTs, noise sources and things to learn. For example, never before were automotive EMC engineer faced with requirements like burst, surge and harmonics & flicker. It is defined as "RESS" Rechargeable Energy Storage System and the latest ECE-R10 now includes an expanded suite of tests for vehicles with electrical drive systems. The requirements are still evolving, so please contact one of our experts who can advise you of the latest requirements and Teseq capabilities for them.
Product
Description
6 dB - 50 Ω attenuators, particularly for minimising reflection losses in tests per IEC/EN 61000-4-6 also useful for general purposes.
The BHA 9118 is a linearly polarised broadband antenna which is ideal for many applications particularly EMC/RF measurements.
1 MHz to 1 GHz 30 Watt Broadband Power Amplifier
1 MHz to 1 GHz 100 Watt Broadband Power Amplifier
80 MHz to 1 GHz 150 Watt Broadband Power Amplifier
80 MHz to 1 GHz 300 Watt Broadband Power Amplifier
80 MHz to 1 GHz 600 Watt Broadband Power Amplifier
80 MHz to 1 GHz 1200 Watt Broadband Power Amplifier
800 MHz to 3.1 GHz 50 Watt Broadband Power Amplifier
800 MHz to 3.1 GHz 100 Watt Braodband Power Amplifier
The compact and modular NSG 5500 solution offers the generators necessary for tests with capacitive discharge pulsed interference as called for by ISO, SAE, DIN and JASO, and others.
800 MHz to 3.1 GHz 300 Watt Broadband Power Amplifier
The NSG 4070 is a multi-functional device for carrying out EMC immunity tests to accompany development and conformity testing in accordance to IEC / EN 61000-4-6, Namur and several automotive BCI standards.
800 MHz to 3.1 GHz 500 Watt Broadband Power Amplifier
0.8 GHz to 4.0 GHz 400 Watt P1dB Single Band Power Amplifier. Tuned for 900 watts CW 1.2-1.4GHz and 600W CW 2.7-3.1GHz
1 GHz to 6 GHz 30 Watt Single Band Power Amplifier
1 GHz to 6 GHz 50 Watt Single Band Power Amplifier
1 GHz to 6 GHz 100 Watt Single Band Power Amplifier
1 GHz to 6 GHz 200 Watt Single Band Power Amplifier
1 GHz to 6 GHz 400 Watt P1dB Single Band Power Amplifier
10 kHz TO 100 MHz 110 Watt Class A Broadband Amplifier
10 kHz to 100 MHz 400 Watt Class A Broadband Amplifier
150 kHz to 230 MHz 35 Watt Class A Broadband Amplifier
150 kHz to 230 MHz 80 Watt Class A Broadband Amplifier
10 kHz to 250 MHz 2500 Watt Class A Broadband Amplifier
10 KHz to 400 MHz 100 Watt Class A Broadband Amplifier
10 kHz to 400 MHz 260 Watt Class A Broadband Amplifier
The CBL 6111 is a high performance ultra wideband BiLog® antenna for emission and immunity EMC testing.
The CBL 6112 operates over the unprecedented, wide range 30 MHz to 2 GHz.
For RF EMC emission and immunity testing in compact anechoic chambers.
The CBL 6143 has a unique matching network which will allow powers of up to 300 watts CW to be transmitted, making it suitable for most immunity measurements requiring fields of 10 V/m, or even greater.
Three phase automatic 32 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge
The CBL 6144 gives an incredible antenna factor of only 3 dB at 26 MHz together with a useable VSWR making the CBL 6144 able to deliver 10 V/m with 80% AM modulation using an amplifier power of less than 500 W (chamber dependent) at 26 MHz.
Three phase automatic 32 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge
Single phase automatic 16 A coupling/decoupling networks (CDNs) for EFT/Burst, Surge, and Power Quality (Dips Interrupts & Variations) testing
Three phase automatic 32, 63 and 100 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge
Three phase automatic 32 A coupling/decoupling networks (CDNs) for EFT/Burst and Surge
Three phase 690 VAC/1000 VDC 100 and 200 A manual coupling/decoupling networks (CDNs) for EFT/Burst
Three phase 440 VAC/DC and 620 VAC/DC 100 and 200 A manual coupling/decoupling networks (CDNs) for Surge
CDN AF Series
CDN CAN Series
CDN M Series
CDN S Series
CDN T Series
The CIP 9136 probe has been manufactured to drawings and specifications laid down by QinetiQ.
Reproducible emissions measurements require a defined line termination for the frequency range where connected lines provide a significant influence on the emissions.
The CFL 9206 assists in preventing damage to input circuits of measuring equipment from high level transients often encountered during conducted emission testing.
Reproducible emissions measurements require a defined line termination for the frequency range where connected lines provide a significant influence on the emissions.
Compliance 5 is sophisticated EMC laboratory control software designed to make RF Emission testing fast, efficient, compliant, accurate and simple.
Compliance 5 is sophisticated EMC laboratory control software designed to make RF Susceptibility/Immunity testing fast, efficient, compliant, accurate and simple.
The CSP 9160 is a broadband RF current sensor probe as defined in CISPR 16-1-2. Beside the compliance measurements of asymmetrical disturbance currents as e.g. required in CISPR 16-2-1 and CISPR 22, the probe can be used in a number of diagnostic applications to measure superimposed RF currents flowing in conductors, or cable harnesses.
This high power dual directional coupler has been specifically designed for EMC immunity applications.
The dipole antenna DPA 3000 operates as a field strength measuring antenna in the frequency range 800 to 2800 (3000*) MHz.
The dipole antenna DPA 4000A operates as a field strength measuring antenna in the frequency range 200 (30*) to 1000 MHz.
Ferrite tube for immunity test according to IEC / EN 61000-4-6, large diameter of 35 mm
The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.
The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing.
The GTEM 750 has a maximum septum height of 750 mm and is suitable for emissions and immunity testing.
The GTEM 1000 has a maximum septum height of 1000 mm and is suitable for emissions and immunity testing.
The GTEM 1250 has a maximum septum height of 1250 mm and is suitable for emissions and immunity testing.
The GTEM 1500 has a maximum septum height of 1500 mm and is suitable for emissions and immunity testing.
The GTEM 1750 has a maximum septum height of 1750 mm and is suitable for emissions and immunity testing.
The GTEM 2000 has a maximum septum height of 2000 mm and is suitable for emissions and immunity testing.
The transversal electromagnetic mode which can developed in the DTEM cell, provides the opportunity for doing EMC testing inside the cell.
The artificial network HV-AN 150 covers several applications and standards in the Automotive, Airborne and MIL range. It
offers the right solution for both high current and high voltage EUTs.
The Input/Output Box, in short IOB 4000, is an ideal addition for electromagnetic immunity test systems.
The ISN PLT is made for measurements on PLT devices which use one port for mains power supply and telecommunications (PLT port).
ISN S series is designed for measurements on coaxial telecommunication lines.
The ISN T2 is designed for measurements on one unscreened balanced pair for cable cat. 3 and cat. 5.
The ISN T4 is designed for measurements on one or two unscreened balanced pairs for cable cat. 3 and cat. 5.
The ISN T8-Cat6 is designed for measurements on up to four unscreened single balanced pairs with cable category cat. 6.
The ISN T8 is designed for measurements on up to four unscreened balanced pairs for cable cat. 3 and cat. 5.
The ITS 6006B consist of an integrated RF signal generator, RF switch and EUT monitoring interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range.
The KEMA 801B is recommended as an additional decoupling network (ferrite tube clamp) for immunity test according to IEC/EN 61000-4-6 when using the clamp injection method.
The normative Annex A of IEC/EN 61000-4-6 gives additional information regarding the clamp injection. The KEMZ 801 is similar to the described EM clamp in the standard and injects the disturbance signal through a combination of inductive and capacitive coupling.
The KSQ 1000 is a special version of reference radiation source for the frequency range 30 MHz to 1 GHz.
The LNA 6000 is a low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz.
The LNA 6900 is a low noise amplifier with 25 dB of gain covering the nominal frequency range 9 kHz to 2 GHz and can be used up to 4 GHz.
The LNA 6901 is a low noise amplifier with typ. 28 dB of gain covering the nominal frequency range 9 kHz to 1 GHz and can be used up to 2 GHz.
The monitoring device MD 4070 can be used as an active or passive current sensor probe to measure the current in a conductor without connecting it directly.
Line impedance stabilization network (LISN) such as the NNB 51 are used to measure distortion signals on the mains cord of an electrical equipment under test (EUT).
Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2, up to 16.5 kV
Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605, up to 30 kV.
Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC61000-4-2 and ISO10605, up to 30 kV.
Electrostatic Discharge (ESD) simulator for immunity testing in compliance with IEC 61000-4-2 and ISO 10605, up to 30 kV. Designed especially for robotic applications.
Programmable AC/DC power source (3 - 15 kVA) for single and three phase applications
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (4.4 kV), Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (4.4 kV), Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (6.6 kV), Surge Telecom 10/700, Ring Wave, Dips Interrupts and Variations, and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
Multifunction generator for EFT/Burst (4.8 kV), Surge Combination Wave (6.6 kV), Dips Interrupts and Variations, Ring Wave (6.6 kV) and Magnetic Field testing. Choice of impulse modules depends on your testing needs.
This battery simulator is designed specifically for automotive EMC testing, Teseq’s 42 V ready power amplifier sets the pace for automotive battery simulation including features necessary for automotive immunity testing such as sense wires for cable voltage drop compensation and several operating modes for stability with complex automotive loads.
This battery simulator designed specifically for automotive EMC testing, Teseq’s 42V ready amplifier sets the pace for automotive battery simulation including features necessary for automotive immunity testing such as sense wires for cable voltage drop compensation and several operating modes for stability with complex automotive loads.
The PCJ 9201 meets all the requirements and provides additionally a save way for measuring the insertion loss of current sensing probes and monitoring probes.
The PMU 6003 is designed for connection to the USB interface. It includes software that allows multiple power meter readouts at the same time.
The PMR 6006 is designed for direct connection to the ITS 6006 Immunity Test System. Up to three power meters can be connected.
The PMU 6006 is designed for connection to the USB interface. It includes software that allows multiple power meter readouts at the same time.
ProfLine 2100 series consists of the measurement part only (ie. single or three phase measurement unit and software). Ideal for users who already have an appropriate amplifier and wish to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
Single phase 3 kVA system to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3. Supporting testing on products consuming up to 11 Arms and 92 A peak @ 230 VAC
Single phase 5 kVA system up to 16 A to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
Three phase 15 kVA system (5 kVA per phase) up to 16 A to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
Three phase 30 kVA system (10 kVA per phase) up to 43 A to measure harmonics and flicker in accordance with IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11 and IEC 61000-3-12.
Three phase 45 kVA system (15 kVA per phase) up to 62 A to measure harmonics and flicker in accordance with IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11 and IEC 61000-3-12.
Reverberation Chambers (RCs) are modern EMC test environments in addition to the established methods like semi- or full anechoic rooms, open area test sites or (G)TEM cells.
Reverberation Chambers (RCs) are modern EMC test environments in addition to the established methods like semi- or full anechoic rooms, open area test sites or (G)TEM cells.
Stirrer size L, remote controlled, incl. gear motor for step-wise and continuous rotation, positioning accuracy +/- 0.5°, smallest step 0.1°, motor installed inside chamber, specified up to 600 V/m CW, incl. EMC filter, cables and stirrer control unit with remote interface and driver for C5I software
Stirrer size M, remote controlled, incl. gear motor for step-wise and continuous rotation, positioning accuracy +/- 0.5°, smallest step 0.1°, motor installed inside chamber, specified up to 600 V/m CW, incl. EMC filter, cables and stirrer control unit with remote interface and driver for C5I software
Stirrer size S, remote controlled, incl. gear motor for step-wise and continuous rotation, positioning accuracy +/- 0.5°, smallest step 0.1°, motor installed inside chamber, specified up to 600 V/m CW, incl. EMC filter, cables and stirrer control unit with remote interface and driver for C5I software
RF Switch Network
The RSG 1000 is a reference spectrum generator for the frequency range from 1 MHz to 1 GHz.
The RSG 3000 is a reference spectrum generator for the frequency range from 1 MHz to 6 GHz.
The transversal electromagnetic mode which can be developped in the SL 50 strip line, provides the opportunity for doing EMC testing inside the strip line.
The transversal electromagnetic mode which can be developped in the SL 90 strip line, provides the opportunity for doing EMC testing inside the strip line.
The transversal electromagnetic mode which can be developped in the SL 150 strip line, provides the opportunity for doing EMC testing inside the strip line.
The SW 4070 allows to switch the signal paths for having a remote controlled system and is fully powered and controlled by the NSG 4070.
The SW 6012 adds two SPDT switches to the built-in switching network of the ITS 6006. It is fully powered and controlled by the ITS 6006.
The UPA 6108 and UPA 6109, suitable for CISPR/IEC/EN, FCC, MIL-STD testing, are small yet rugged antennas covering the frequency range 200 MHz - 1 GHz (UPA 6109), and 300 MHz - 1 GHz (UPA 6108).
The UPA 6108 and UPA 6109, suitable for CISPR/IEC/EN, FCC, MIL-STD testing, are small yet rugged antennas covering the frequency range 200 MHz - 1 GHz (UPA 6109), and 300 MHz - 1 GHz (UPA 6108).
The UPA 6192 antenna is hybrid antenna with the characteristics similar to a broad band dipole in the range 30 - 200 MHz and a log periodic antenna in the range 200-2000 MHz.
The VBA 6106A is suitable for CISPR/EN, FCC and MIL-STD testing across the frequency range 30-300 MHz.
The VSQ 1000 is a radiation source for the frequency range from 30 MHz to 1 GHz.
The VSQ 3000 (VSQ 3002) is a radiation source for the frequency range from 800 MHz (30 MHz) to 3 GHz.
Teseq provides with the WIN 6000 a device control software with NSG 4070 and ITS 6006 for performing conducted and radiated susceptibility tests as defined by international standards.
AMETEK CTS GmbH
Sternenhofstr. 15
4153 Reinach, Switzerland
Tel.+ 41 61 204 41 00
marketing.cts@ametek.com
Managing Directors:
Brian Huntsman
Astrid Wälchli Schreiber
VAT-ID: CHE-179.452.414
Register of companies: CH-280.4.015.069-3